mmWave-UPM Lab logo

The mmWave-UPM Lab is a state-of-the-art 5G research facility specializing in FR2 over-the-air (OTA) testing, fully compliant with 3GPP conformance standards

This unique UPM facility provides comprehensive OTA testing in accordance with 3GPP TS 38.521, covering both uplink and downlink directions: transmit power, power dynamics, signal quality, RF spectrum, Rx sensitivity, and adjacent channel selectivity, across a wide temperature range from –40 to 85 °C

The mmWave-UPM Lab enables precise validation of next-generation user equipment under real-world and thermal stress conditions.

EQUIPMENT

ATS1800C Compact Antenna Test Range

Indirect Far Field Anechoic Chamber for mmWave Over-the-Air (OTA) measurements.

• Frequency range: 6 GHz92 GHz (in-band 23.5–44.3 GHz)

• Quiet Zone (QZ): 40 cm diameter.

• Integrated dual-polarized feed antennas.

• DUT positioner: Azimuth and elevation ±181°, resolution 0.01°,     load up to 8 kg

ATS-1800C mmWave CATR chamber - inside
ATS-1800C mmWave CATR chamber - close
CMX-500 image

CMX500

5G base station emulator for conformance and signaling tests.

• Frequency range: FR1 (sub-6 GHz) and FR2 (24.25 – 52.6 GHz)

• Supports Standalone (SA) and Non-Standalone (NSA) 5G         modes

• Maximum data rate: 20 Gbps

• Supports TDD/FDD, beamforming control, and dual-carrier         aggregation

FSW85

High-performance spectrum analyzer FR1 and FR2.

• Frequency range: 2 Hz – 90 GHz

• Frequency resolution 0.01 Hz

• Minimum sensitivity without preamplifier: −155 dBm

• Supports TRP, EIRP, spurious emission, and phase noise tests

FSW85 - close up image
CMX-RF42 close up image

CMX-RF42

RF up-/down-conversion and amplification for FR2 signal paths.

• Frequency range: 24 GHz – 44 GHz

• Supports uplink (UL) and downlink (DL) conformance paths

• Low-noise amplifier for receiver path; variable gain for                 transmitter path

• Ensures proper SNR and dynamic range for TRP/EIRP testing

MPI TA-5000 – Thermal Streamer

Temperature control system for DUT environmental testing.

• Temperature range: –40 °C to +85 °C

• Stability: ±1 °C; programmable thermal cycling

• Provides hot/cold airflow directly into the DUT chamber

• Temperature resolution: 0.1ºC

MPI-TA-5000 close up image

The mmWave-UPM Lab is equipped to perform comprehensive 5G FR2 device testing across both unlicensed and licensed frequency bands, including the 24 GHz band and the n258 (26 GHz), n257 (28 GHz), n260 (39 GHz), n259 (41 GHz) bands. This capability enables end-to-end evaluation of next-generation user equipment under realistic operating conditions.

TEST CASES

5G FR2 Standalone (SA)

In Standalone mode, the mmWave-UPM Laboratory operates a complete 5G New Radio (NR) system

Products / Materials tested Type of test Standard Specifications / Test procedure
5G User Equipment (UE): smartphones, tablets, laptops, FWA and others.UE Conformance tests. Frequency Range 2 Operation. Applicability to stand-alone Radio Transmission: 5G Tx FR2 (SA)UE Maximum Output Power 3GPP TS 38.521-3
ETSI TS 138 521-3
Ver 18.
Clause 6.1 to 6.4

3GPP TS 38.521-4
ETSI TS 138 521-4
Ver. 18
Clause 4.5, 7.1 to 7.5
On/Off Behavior
Power Tolerance
Frequency / Modulation
Bandwidth and emissions
Spurious Emissions
CA-specific In-band emissions
CA Occupied Bandwidth
UE Conformance tests. Frequency Range 2 Operation. Applicability to stand-alone Radio Reception: 5G Rx FR2 (SA)Receiver Performance3GPP TS 38.521-3
ETSI TS 138 521-3
Ver 18.
Clause 7.1 to 7.9

3GPP TS 38.521-4
ETSI TS 138 521-4
Ver. 18
Clause 4.5, 7.1 to 7.5
Maximum Input
In-band measurments
Out-of-band measurements
Beam management
Maximum Input
In-band measurements
Out-of-band measurements

5G FR2 non-Standalone (NSA)

Products / Materials tested Type of test Standard Specifications / Test procedure
5G User Equipment (UE): smartphones, tablets, laptops, FWA and others.UE Conformance tests. Frequency Range 1 and 2 EN-DC Interworking Operation. Applicability to non-stand-alone Radio Transmission: 5G Tx FR1-FR2 (NSA)UE Maximum Output Power 3GPP TS 38.521-3
ETSI TS 138 521-3
Ver 18.
Clause 6.1 to 6.4

3GPP TS 38.521-4
ETSI TS 138 521-4
Ver. 18
Clause 4.5, 7.1 to 7.5
On/Off Behavior
Power Tolerance
Frequency / Modulation
Bandwidth and emissions
Spurious Emissions
UE Conformance tests. Frequency Range 1 and 2 EN-DC Interworking Operation. Applicability to non-stand-alone Radio Reception: 5G Rx FR1-FR2 (NSA)Receiver Performance3GPP TS 38.521-3
ETSI TS 138 521-3
Ver 18.
Clause 7.1 to 7.9

3GPP TS 38.521-4
ETSI TS 138 521-4
Ver. 18
Clause 4.5, 7.1 to 7.5
Maximum Input
In-band measurements
Out-of-band measurements
Beam management

Universidad Politécnica de Madrid logo
TELECO Campus sur UPM logo

Contact us

Copyright © 2025 UPM Radiocommunications Group